The YTG series features patented brushless, synchronous generators with built-in silicon rectifier rotors.With no carbon brushes, generator maintenance is easier. |
Another advantage of brushless generators is low wave interference, providing the suitable power source for telecommunications equipment. |
||
A built-in silicon rectifier rotor functions as a sort of AVR. Fluctuation from no load to 100% load is very low level. (YTG-T) Compensation winding is used to control single-phase voltage fluctuation. Fluctuation is low even when the single phase loads between O-R, O-S, and O-T are unbalanced. This facilitates use of three-phase motors and single phase electrical appliances at the same time. |
With the use of vibration-proof rubber mounts and a well-balanced design, vibration is kept to a minimum. Durability and operational ease are enhanced. |
||
The electromagnetic circuit breaker automatically interrupts the electrical circuit, if there is an overload or short-circuit, protecting the gene-rotor and the engine. |
|
||
|
|||
SPECIFICATIONS
SPECIFICATION |
Single Phase (2 Wire) | 3 Phase (4 Wire) | ||||||||
| YTG5.0S | YTG6.5S | YTG10S | YTG5.0T | YTG6.5T | YTG9.0T | YTG12.5T | YTG15T | |||
Altemator |
Model |
MR1-180/2 | MR2-160/2 | MR2-200/2 | EC03-1S | EC03-1S | EC03-2S | EC03-3S | EC03-1L | |
Weight |
kg |
33.2 | 50 | 57 | 57 | 57 | 63 | 69 | 78 | |
Insulation
Class |
H | |||||||||
Operation
Condition |
Ambient temperature not exceeding 50℃ | |||||||||
| Attitude not exceeding 1000m | ||||||||||
Engine |
Model |
TF90M | TF120M | TF160M | TF70M | TF90M | TF120M | TF160M | TS190R | |
Type |
Horizontal water-cooled, 4-cycle diesel engine | |||||||||
Bore
x stroke |
mm |
85x87 | 92x96 | 102x105 | 78x80 | 85x87 | 92x96 | 102x105 | 110x106 | |
Displacement |
liters |
0.493 | 0.638 | 0.857 | 0.382 | 0.493 | 0.638 | 0.857 | 1.007 | |
Cont
output |
hp |
8.5 | 10.5 | 14 | 6 | 8.5 | 10.5 | 14 | 16 | |
Rated output |
hp |
9.5 | 12 | 16 | 7 | 9.5 | 12 | 16 | 19 | |
Revolution |
rpm |
2400 | 2200 | |||||||
Starting system |
Hand Start | |||||||||
Cooling
system |
Radiator | |||||||||
Lubricating
system |
Fully sealed forced lubrication with trochoid pump & hydraulic regulator valve | |||||||||
Combustion
system |
Direct injection | |||||||||
Fuel consumption |
lit./h |
2.2 | 2.8 | 3.5 | 1.7 | 2.2 | 2.8 | 3.5 | 4 | |
Fuel
tank capacity |
liters |
10.5 | 11 | 14.3 | 7.1 | 10.5 | 11 | 14.3 | 13.7 | |
Generator Set |
Capacity |
KVA |
5 | 6.5 | 10 | 5 | 6.5 | 9 | 12.5 | 15 |
KW |
5 | 6.5 | 10 | 4 | 5.2 | 7.2 | 10 | 12 | ||
Frequency |
Hz |
Available in either 50Hz or 60Hz | ||||||||
Revolutions |
rpm |
3000 for 50Hz/3600 for 60Hz | ||||||||
No . of phase |
Single Phase | 3 Phase (4 wire) | ||||||||
Power
factor |
1 | 0.8 | ||||||||
Excitation
system |
Brushless, self-excitation system | |||||||||
Drive
system |
V-belt drive | |||||||||
Voltage (Standard) |
V |
220 | 220/380 | |||||||
Recommend cable dia |
mm |
6-16 | ||||||||
Recommend
earth cable |
Equal to the conductor size | |||||||||
Ampere |
A |
22.7 | 29.5 | 45.5 | 7.6 | 9.9 | 13.7 | 19 | 22.8 | |
Dimension |
Length |
mm |
1270 | 1360 | 1410 | 1270 | 1270 | 1360 | 1410 | 1530 |
Width |
mm |
610 | 690 | 700 | 610 | 610 | 690 | 700 | 740 | |
height |
mm |
760 | 800 | 850 | 760 | 760 | 800 | 850 | 920 | |
Net
weight (dry) |
kg |
219 | 227 | 339 | 214 | 224 | 290 | 353 | 384 | |



All the
TF engines feature enlarged cylinder volumes
to increase displacement, output, and power.
Their direct fuel injection system decrease
energy and thermal losses. And the TF engines
generate high output throughout the model line
thanks to the Yanmar injection nozzle, a unique
fuel injection pump and a specially developed
toroidal-shaped combustion chamber.